Vacuum Generator, Unitasking
Vacuum Generator VY
Integration of ejector and blow-off (vacuum break) functions.
Advantages
Integration of ejector and blow-off (vacuum break) functions.
Integration of ejector and blow-off (vacuum break) functions. Switchover from vacuum generation to blow-off air is possible by applying or stopping supply air to ejector.
Ejector is equipped with blow-off (vacuum breaking) air function.
Compared with the conventional single stand-alone type ejector, reliable blow-off(vacuum break) is possible.
Greatly improved price compared to conventional vacuum generators with solenoid valve.
Small size and lightweight. Installation at the end of vacuum circuit is possible
High cycle of suction and blow-off is realized by the equipped shut-off valve.
Specifications
Fluid medium | Air (JIS B 8392-1:"Class 1.2.1~2.4.3") |
---|---|
Operating pressure range | 0.3~0.7MPa |
Rated supply pressure | 0.5MPa (H, L type)/0.35Mpa (E type) |
Operating temp. range | 5~50℃ (No freezing) |
Refueling | Not required |
Spec. of Vacuum filter for VY
Fluid medium | Air |
---|---|
Operating pressure range | -10~0kPa |
Filtering accuracy(*) | 5μm (Trapping efficiency:95%) |
Operating temp. range | 0~60℃(No freezing) |
Filter area | Port size 44:0.8mm2/Port size 66:1.1mm2 |
Material:PVF (Polyvinyl Formal) |
* Based on our measurement conditions.
Port size
Vacuum port
Tube dia.
mm Size (mm) | φ4, φ6, |
---|---|
Inch Size | φ1/4" |
Air supply port
Tube dia.
mm Size (mm) | φ4, φ6, |
---|---|
Inch Size | φ1/4" |
Exhaust port
Tube dia. (Exhaust port)
mm Size (mm) | φ6, |
---|---|
Inch Size | φ1/4" |
Vacuum Characteristic Graph
Construction
Type & Price list
Option & Maintenance items
Detailed Safety Instructions
3.Knurling locknut needs to be tightened firmly by hand without using any tool. Using tools to tighten the nut may cause damage to the nut or the product. Inadequate tightening may loosen the locknut and the initial setting may be changed.
Caution
1.Read and understand the instructions carefully when adjusting the flow rate and breaking time of the blow-off (vacuum breaking) air of the vacuum generator VY.
2.The vacuum filter for the vacuum generator VY cannot be replaced by the filter element alone. When the filter is replaced for maintenance or inspection, the filter itself must be replaced.
3.If different pressures are used for the supply air for vacuum generation and blow-off (vacuum breaking) of the vacuum generator VY, the pressure of the supply air for blow-off (vacuum breaking) must be set below the pressure of the supply air for vacuum generation. If the supply air pressure for blow-off (vacuum breaking) is higher than the supply air pressure for vacuum generation, it may lead to leakage.
4.When the vacuum generator VY is used in the piping method shown in the following figure, blow-off air from the check valve turns around and the blow-off air comes out of the V (vacuum) port, although it is instantaneous until the shut-off valve is completely switched off.
5.Do not apply excessive force when attaching the tube to the vacuum filter for the vacuum generator VY. The filter may be damaged.
Inquiries about this product