Tube
Fluoropolymer (FEP) Tubing
Superior cost performance compared to SFT tubes.
Bending radius
-
5Color
Advantages
Superior cost performance compared to our SFT tubes.
Extruded from fluoropolymer(FEP) which is excellent in chemical resitance
Best suitable for chemical, food, medical care and semiconductor industries
Extensive service temperature range
Inch size models, perfect to be used with the inch-sized SUS316 compression fitting are prepared
Cleanroom wash/packaging is available
Cleaning and packing in cleanroom ISO class 6 equivalent.
Tube overview
Tube color samples
Actual colors may vary due to the different display methods on your computer monitor.
Specifications
SET0420
Fluid medium | Air, Water (Conditional *1), Water (Conditional *1), Others such as chemicals (Conditional *1) |
---|---|
Max. operating pressure (65%RH at 20º) | 2.7MPa *2 |
Max. vacuum | -100kPa |
Operating temperature range | -65~200ºC (No freezing) |
Warning
*1. Adhere to the following conditions in case the fluid is water or any liquids.
Surge pressure must be controlled lower than max. operating pressure when using water or any liquids as a fluid medium.
Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water.
Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium.
Can be used with a broad range of chemicals but please check the chemical compatibility before use.
*2. The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve.
SET0425, SET0640
Fluid medium | Air, Water (Conditional *1), Chemicals (Conditional *1) |
---|---|
Max. operating pressure (at 20ºC 65%RH) | 1.6MPa (*2) |
Max. vacuum | -100kPa |
Operating temperature range | -65~200ºC (No freezing) |
Warning
*1. Adhere to the following conditions in case the fluid media is water or any liquids.
Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium.
Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water.
Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium.
Can be used with a broad range of chemicals but please check the chemical compatibility before use.
*2. The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve.
SET1/4, SET3/8, SET1/2, SET0860, SET1075, SET1290
Fluid medium | Air, Water (Conditional *1), Others such as chemicals (Conditional *1) |
---|---|
Max. operating pressure (at 20ºC 65%RH) | 1.0MPa (*2) |
Max. vacuum | -100kPa |
Operating temperature range | -65~200ºC (No freezing) |
Warning
*1. Adhere to the following conditions in case the fluid medium is water or any liquids.
Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium.
Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water.
Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium.
Can be used with a broad range of chemicals but please check the chemical compatibility before use.
*2. The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve.
SET1080, SET1210, SET1613
Fluid medium | Air, Water (Conditional *1), Others such as chemicals (Conditional *1) |
---|---|
Max. operating pressure (at 20ºC 65%RH) | 0.7MPa (*2) |
Max. vacuum | -100kPa |
Operating temperature range | -65~200ºC (No freezing) |
Warning
*1. Adhere to the following conditions in case the fluid medium is water or any liquids.
Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium.
Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water.
Be sure to place Insert Ring (WR) into the tubing end when the the tubing is inserted into Push-in Fitting with water or any liquids oil as a fulid medium.
Can be used with a broad range of chemicals but please check the chemical compatibility before use.
*2. The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve.
Port size
Inch size
O.D.xI.D.(φin) | 1/4x0.180, 3/8x0.275, 1/2x3/8 |
---|
Metric size
O.D.xI.D.(φmm) | 4x2, 4x2.5, 6x4, 8x6, 10x7.5, 10x8, 12x9, 12x10, 16x13 |
---|
*4mm O.D.(4x2) is the same as 5/32" O.D.(5/32x0.079), 4mm O.D.(4x2.5) is 5/32" O.D.(5/32x0.098), 8mm O.D. is 5/16" O.D.(5/16x0.236), 16mm O.D. is 5/8" O.D.(5/8x0.512) as well
Type & Price list
mm size
Inch size
Detailed Safety Instructions
Warning
1.In case of using with chemicals, solvents or mixed gases, please check the chemical compatibility before use. Incorrect use could result in breakdown of fittings, fluid leakage or tubing falling off
2.Even though the evaluation on the chemical resistance chart shows positive with FEP material, there is a possibility that problems may occur due to factors such as temperature, pressure or physical action by stress. Before permanent installation, test the equipment with the chemicals under the specific conditions of your application, especially for applications with solvents
3.Avoid using in areas prone to vibrations.
4.For long-term use, it is recommended to use Compression Fittings. Due to material degradation over time, leaks may occur. Perform regular maintenance, and promptly replace the product if any leaks are detected.
Inquiries about this product
It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.
The following are frequently asked questions. Please check before making inquiries.